The models all performed well in cross validation against the distributions used to generate the model; however, a model generated based on data that does not contain representatives from all of the ASTM E1618-14 classes did not perform well in validation with data sets that contain representatives from the missing classes. A quadratic discriminant model based on a balanced data set (ignitable liquid versus substrate pyrolysis), with a uniform distribution of the ASTM E1618-14 classes, performed well (receiver operating characteristic area under the curve of 0.836) when tested against laboratory-developed, casework-relevant samples of known ground truth. (publisher abstract modified)
Downloads
Similar Publications
- Cognitive and contextual influences in determination of latent fingerprint suitability for identification judgments
- The Cross-Reactivity of the Cannabinoid Analogs (delta-8-THC, delta-10-THC and CBD) and their metabolites in Urine of Six Commercially Available Homogeneous Immunoassays, Grant Report
- Introducing "DoPP": A Graphical User-Friendly Application for the Rapid Species Identification of Psychoactive Plant Materials and Quantification of Psychoactive Small Molecules Using DART-MS Data